Injection route to the human cochlear modiolus

Hearing loss can be remedied with various devices, such as a hearing aid, but medical prevention and medical treatment of hearing loss is moving closer to realisation. Oticon, a company which produces hearing aids and respective supplies is also engaged in current research on hearing loss. Oticon is currently running a research project on such medicine that will be administered directly into the cochlear in the inner ear. In here, initial understanding and mastering of the delivery route to the human cochlear will be key to succeed and to potentially bring the therapy to future human patients. Injection into the cochlear modiolus has been used in animal studies, but only demonstrated in a single study on human species temporal bones and is not a surgery routinely done among ear-nose-throat surgeons. Therefore, Oticon engaged with the 3D Imaging Centre to perform micro–X-ray Computed Tomography (CT) to learn more about the feasibility of performing an intramodular injection into the human cochlea.
An electrode probe inserted into the cochlear modiolus in a human specimen temporal bone.
3D reconstruction of the cochlear with the electrode probe inserted

Challenge

Visualisation of a targeted position in the cochlear modiolus can be done with histology but this destroys the studied sample and only allows 2D representation. In contrast, X-ray Computed Tomography is a non-destructive imaging method that offers 3D representation of the studied sample. Collaboration The temporal bone was prepared at the Panum Institute, University of Copenhagen, and investigated using micro–X-ray Computed Tomography (CT) at the 3D Imaging Centre at DTU. This collaboration was part of the LINX project, in which researchers at leading Danish universities collaborate with scientists in industry to solve industry relevant problems using advanced neutron and X-ray techniques. Besides projects for the members of the LINX association, the LINX project also supports outreach projects for companies, which are not members of the LINX association. In this way, companies can test how they can benefit from X-ray- and neutron-based techniques.

Results

The cochlear modiolus was surgically accessed in a human specimen temporal bone, and a tungsten electrode probe (Ø 127 µm) was inserted into the modiolus via the second cochlear turn to mark the achieved intramodular position. The specimen was studied using micro X-ray CT. 3D reconstruction of the results allowed verification of the target site in the modiolus (tip of the probe) and calculation of the trajectory route (bottom figure).

Perspectives

The data shows that surgically access, and thereby potential of delivering medicine, to the cochlear modiolus is possible. Data on more temporal bones are needed to reproduce the findings and to characterise the target spot in the modiolus more systematically